Sign In | Join Free | My himfr.com
Home > UTP CAT6 Cable >

1000Mbps Cat 6 UTP Outdoor Network Cable 23AWG Solid PVC+PE Extend To 550MHz

Integrity Cable Co., Limited
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap 1000Mbps Cat 6 UTP Outdoor Network Cable 23AWG Solid PVC+PE Extend To 550MHz from wholesalers
     
    Buy cheap 1000Mbps Cat 6 UTP Outdoor Network Cable 23AWG Solid PVC+PE Extend To 550MHz from wholesalers
    • Buy cheap 1000Mbps Cat 6 UTP Outdoor Network Cable 23AWG Solid PVC+PE Extend To 550MHz from wholesalers
    • Buy cheap 1000Mbps Cat 6 UTP Outdoor Network Cable 23AWG Solid PVC+PE Extend To 550MHz from wholesalers
    • Buy cheap 1000Mbps Cat 6 UTP Outdoor Network Cable 23AWG Solid PVC+PE Extend To 550MHz from wholesalers

    1000Mbps Cat 6 UTP Outdoor Network Cable 23AWG Solid PVC+PE Extend To 550MHz

    Ask Lasest Price
    Brand Name : ITI-LINK
    Certification : UL, ETL, CSA, RCM, TUV, CPR, CE, RoHS
    Model Number : ITI-CT6OUT-001
    Price :
    Delivery Time : 15-45Days
    Payment Terms : T/T
    Supply Ability : 1500pcs/day
    • Product Details
    • Company Profile

    1000Mbps Cat 6 UTP Outdoor Network Cable 23AWG Solid PVC+PE Extend To 550MHz

    Cat6 Outdoor UTP High Speed Network Cable 23AWG Extend to 550MHz Solid PVC+PE 1000FT


    Quick Detail:


    · Core wire selection, solid pure copper as the conductor.

    · The basic bandwidth is 250MHz and can be expanded to 550MHz.

    · The outer layer adopts a double-layer structure of PVC+PE, 60P, -20~75℃

    · Cat6 Cable Rate temperature:60℃ 75℃

    · UTP Cat 6 Cable InstallationTemperature: -30℃-+50℃

    · Complies to ANSI/TIA-568-B.2&IS0/IEC11801

    · UL compliant, TUV, CPR, ETL, CSA, RCM, ISO9001, CE, RoHS


    Description:


    > Cat6 UTP Outdoor Cable Provide 250MHz bandwidth within a distance of 90 meters. The typical application rate is 1000Mbps.


    >Cat6 Outdoor Cable selects high-quality oxygen-free copper as the transmission conductor. At the same time, it adopts the design of a central cross-shaped PE skeleton to separate four individual pairs.


    >The outer layer of Cat6 outdoor UTP network cable adopts a PVC+PE double-layer structure, which has stronger wear resistance and aging resistance. Can be well applied to outdoor wiring operations.


    >Cat 6 cable is suitable for outdoor environments and has good weather resistance, waterproof performance, and ultraviolet resistance. It can be used for a long time under harsh outdoor conditions.



    Product Description
    1Inner Conductor
    2Insulation
    3Cross Member
    4Inner Jacket
    5Ripcord
    6Outer Jacket

    Specifications:


    Product Description: CAT6 U/UTP 23AWG Solid Outdoor PE+PVC Cable
    Rev.: AECN Description:
    Construction Item DescriptionElectrical Property

    Conductor


    Material

    Bare Solid Copper(elongation:

    19 ~ 24%)

    Conductor Resistance at 20°C≤ 9.5 Ω / 100m
    OD23 AWGResistance unbalance within a pair≤ 2%

    Insulation


    Material


    HDPE 8303

    Insulation Resistance at 20°C after 2min of electrification under a DC voltage between 100 & 500V

    >1500 MΩ / 100m

    OD1.14 ± 0.05 mmMutual capacitance5600 pF / 100m MAX
    Average THK0.29 mmCapacitance unbalance pair to ground at 800Hz or 1 kHz≤ 160 pF / 100m

    Color

    1p: white + 2 blue stripes & blueCharacteristic impedance at 100MHz100 ± 15 Ω

    2p: white + 2 orange stripes &

    orange

    Dielectric Strength Test Voltage (cd/cd,cd/screen): 1.00KV DC or

    0.7 KV AC for 1 min


    No breakdown

    3p: white + 2 green stripes & greenMechanical Property
    4p: white + 2 brown stripes & brown

    insulation

    elongation before aging≥ 300%

    Pair Twist


    Lay & Direction

    1p: S=20.0 mm (28%)tensile strength before aging≥16 MPa
    2p: S=17.5 mm (24%))elongation after aging≥ 150 %
    3p: S=22.0 mm (32%)tensile strength after aging≥10.5 MPa
    4p: S=15.5 mm (21%)

    jacket

    elongation before aging≥350%
    OD/tensile strength before aging≥9.7MPa

    Inner Assemble

    LayS=90 ± 5 mmelongation after aging≥263%
    Directionaccording to the drawingtensile strength after aging≥7.3MPa
    Filler/Packing
    OD/Inner BoxNA
    FillerMaterialRipcordMaster CartonNA
    Construction300D

    Outside Shield

    Shield/
    Construction/
    Material/
    Coverage/

    Jacket

    MaterialInner Jacket: PVC + Outside Jacket: PE
    Hardness/
    OD5.8 / 7.2
    Average THK/

    Color

    BLACK

    Marking Color

    WHITE

    Marking

    according to the customer's requirements

    Construction Item Description

    Conductor

    ConstructionAWG23
    Material/Bare Solid Copper

    Insulation

    Material/HDPE 8303
    Proportiong/cm³0.97
    Outside Diametermm1.14 ± 0.05
    Average Thicknessmm0.29

    Color


    /

    1p: blue stripe + white + blue stripe & blue
    2p: orange stripe + white + orange stripe & orange
    3p: green stripe + white + green stripe & green
    4p: brown stripe + white + brown stripe & brown

    Pair Twist


    Lay & Direction


    /

    1p: S=20.0 mm (28%)
    2p: S=17.5 mm (24%)
    3p: S=22.0 mm (32%)
    4p: S=15.5 mm (21%)
    Inner AssembleLay & Direction/S=90 ± 5 mm

    Filler

    Ripcord/300D
    Cross Member/HDPE

    Outside Shield

    Shield//
    Constructionmm/
    Material//
    Coverage%/

    Jacket

    Material/Inner Jacket: PVC + Outside Jacket: PE
    HardnessA/
    Outside Diametermm5.8 / 7.2
    Average Thicknessmm/
    Color/BLACK
    Marking Color/WHITE
    MarkingJacket/according to the customer’s requirements

    Electrical Properties
    Conductor Resistance at 20°C

    UL 444 & CSA C22.2 No. 214

    ≤ 9.5 Ω / 100m
    Resistance unbalance within a pair≤ 2%

    Dielectric Strength

    Test Voltage (cd/cd): 1.00KV DC or 0.7 KV AC for 1 min Test Voltage (cd/screen): 1.00KV DC or 0.7 KV AC for 1 min


    No breakdown

    Insulation Resistance at 20°C after 2min of electrification under a DC voltage between 100 & 500V

    >1500 MΩ / 100m

    Mutual capacitance5600pF / 100m MAX
    Capacitance unbalance pair to ground at 800Hz or 1 kHz≤ 160 pF / 100m
    Characteristic impedance at 100MHz100 ± 15 Ω
    Spark Test2000 ± 250VOC

    Transmission Properties
    CAT 6 U/UTP

    No.


    Frequency


    Attenuation (Max)

    Propagation Delay (MAX)Propagation Delay Skew (MAX)

    Return Loss (Min)


    NEXT (Min)


    PS NEXT (Min)


    EL-FEXT (Min)


    PS EL-FEXT (Min)

    MHzdB/100mns/100mns/100mdB(on 100m)dB(on 100m)dB(on 100m)dB(on 100m)dB(on 100m)
    143.785524523.0166.2763.2755.9652.96
    285.32546.734524.5261.7558.7549.9446.94
    3105.95545.38452560.357.34845
    4167.55543452557.2454.2443.9240.92
    5208.47542.05452555.7852.7841.9838.98
    6259.51541.24524.3254.3351.3340.0437.04
    731.2510.67540.444523.6452.8849.8838.135.1
    85013.66539.094522.2149.8246.8234.0231.02
    962.515.38538.554521.5448.3645.3632.0829.08
    1010019.8537.64520.1145.342.32825
    1112522.36537.224519.4343.8540.8526.0623.06
    1220028.98536.55451840.7837.7821.9818.98
    1325032.85536.284517.3239.3336.3320.0417.04
    14
    15
    16
    17
    18
    Remarks: * are the reference values.

    Notices:


    1. Open the packaging, check the products carefully, and take them gently.

    2. Please strictly follow the wiring standards during construction, and do not tie or excessively bend the network cables.

    3. When making RJ45 network cable connectors, please follow the T568B or T568A standards to ensure the correct wire sequence and avoid problems such as disconnected lines or unstable network connections.

    4.It is best to use a single network cable at a distance of no more than 100 meters to ensure optimal transmission performance.

    5. Ensure that the shielded network cable is grounded during installation.


    Applications:


    Widely used in office buildings, schools, research institutions, airports, high-speed trains, hospitals, hotels, industries, shopping malls, supermarkets, etc.



    FAQ

    UL/CE/RoHS/ETL/CPR Certificate Lan cable Cat6 U / UTP 23AWG Extend to 550MHz Solid Outdoor PVC+PE HIGH SPEED NETWORK

    Q1. Can I order samples of Lan cables?

    A: Yes, we welcome sample order to test and check quality.


    Q2. What about the lead time?

    A: 3-5 days for Sample preparing ,8-10 working days for mass production.


    Q3. Do you have a minimum order quantity limit for network cable orders?

    A: Low MOQ, 1pc for sample checking is available.


    Q4. How do you ship the goods and how long does it take to arrive?

    A: We usually ship by sea, which usually takes about 7 days to arrive.


    Q5. How to proceed an order for network cable?

    A: Firstly let us know your requirements or application.

    Secondly We quote according to your requirements or our suggestions.

    Thirdly customer confirms the samples and places deposit for formal order.

    Fourthly We arrange the production.


    Q6.Is it OK to print my logo on network cable product?

    A: Yes. Please inform us formally before our production.


    Q7: Do you offer guarantee for the products?

    A: Yes, we offer 10 years warranty to our products.


    Q8: How to deal with the faulty?

    A: Firstly, Our products are produced in strict quality control system and the defective rate will be less than 0.2%.


    Secondly, for individual defective products, we will remedy them as soon as possible and send them to you, or we can discuss solutions based on the actual situation to achieve 100% satisfaction for you.


    Quality 1000Mbps Cat 6 UTP Outdoor Network Cable 23AWG Solid PVC+PE Extend To 550MHz for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Integrity Cable Co., Limited
    *Subject:
    *Message:
    Characters Remaining: (0/3000)